Plasma nozzle dia.
3.0 mm
This table is only valid for the PTW 3500 in conjunction with an FK 9000 cooling
unit
Plasma nozzle dia.
2.0 mm
2.5 mm
3.2 mm
3.5 mm
4.0 mm
This table is only valid for the PTW 3500 in conjunction with a CHILLY 15 cooling
unit
Plasma nozzle dia.
2.0 mm
2.5 mm
3.2 mm
3.5 mm
4.0 mm
* Correction factor of the plasma module must be on Automatic
Minimum rate of plasma gas flow:
gas flow rate at which the welding arc just remains stable.
NOTE!
Welding using a minimum plasma gas flow places a severe load on the plasma
nozzle and should be avoided.
Maximum welding current:
welding current that is permitted for a particular plasma nozzle, with the standard tungs-
ten electrode setting, the minimum plasma gas flow rate and depending on the cooling
unit.
Example PTW 1500:
in the case of a plasma nozzle with a diameter of 2.0 mm and a specified minimum
plasma gas flow rate of 0.25 l/min, a maximum welding current of 80 A is permitted for
the standard tungsten electrode setting.
NOTE!
Use pure argon as the plasma gas.
The limit values listed above can only be obtained using pure argon.
Plasma gas flow rate *
Min. 0.55 l/min
Max. 1.30 l/min
Plasma gas flow rate *
Min. 1.0 l/min
Min. 1.0 l/min
Min. 1.0 l/min
Min. 1.0 l/min
Min. 1.0 l/min
Plasma gas flow rate *
Min. 1.0 l/min
Min. 1.0 l/min
Min. 1.0 l/min
Min. 2.0 l/min
Min. 2.0 l/min
Max. welding current
130 A
150 A
Max. welding current
170 A
190 A
210 A
225 A
250 A
Max. welding current
225 A
250 A
275 A
300 A
350 A
25