Safety notes for maintenance and troubleshooting on the
MaxiFil Clean device
Preparation, maintenance and repair works, as well as error detection can only be
performed with the welding fumes filter in a de-energized state.
Bolted joints, loosened during maintenance and repair works, shall always be
tightened! If specified, the relevant bolts must be tightened with a torque wrench.
At the beginning of maintenance/repair/care it is particularly necessary to remove
impurities from connections and bolted joints.
Observe the intervals for periodic tests/checks specified or mentioned in the
Instruction Manual.
Capture the mutual positions of each component prior to disassembly!
2.6

Caution with Respect to Special Risks

Electric Installation
Works on the electric equipment of the filtration unit may only be carried out by a
qualified electrician or trained staff managed and supervised by a qualified electrician
in accordance with electrical regulations!
Prior to opening the device, pull the mains plug out from the wall outlet to prevent the
accidental start of the unit.
In case of a power failure, switch the filtration unit off immediately using the On/Off
button and remove the plug from the outlet!
Only use original fuses with the specified current values!
The electrical components on which inspection, maintenance and repair works shall
be free of voltage. The mains disconnection device must be secured against
unwanted or spontaneous restart. In case parts are disconnected from the mains,
first determine whether they are not powered and then insulate the adjacent
components, which are powered. During repair efforts, make sure no changes are
made to structural characteristics that could result in decreased safety.
Check cables for damage regularly and replace them if necessary.
Noise level
The equivalent level of acoustic pressure A of the filtration device LpA ≤ 72 dB(A).
The level of acoustic pressure in the place of application of the filtration unit may be
higher depending on other machines and/or local circumstances. In such case, the
operator has the duty to provide the operators with suitable personal protection
equipment.
KEMPER MaxiFil Clean Instruction manual - EN
- 45 –
Technical changes and errors reserved.