Descargar Imprimir esta página

Zenit UNIQA Serie Manual De Instalacion Y Uso página 50

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
Safety, Installation and Operations Manual – Translation of original instructions
5. Place the vessel containing the oil on a horizontal surface and let it stand for a few minutes to allow any water in it to settle to the bottom:
Oil clean and free from water: the mechanical seal is in good condition and new oil can be placed in the system.
EN
Oil with a very little water: this may be due to bedding-in of the mechanical seal during the initial operating hours, creating a negligible
amount of water.
Oil containing water and dirt; the mechanical seal must be inspected and replaced with a new one. The replacement must be made
by an authorised Service Centre;
50
4. Allow the oil to drain into a vessel of suitable size, transparent if possible.
6. Lay the pump horizontal on the workbench
7. Fill the mechanical seal sump with lubricating oil.
Enclosure type
G05M
G05L
G06S - G06L
G07S - G07L
G08L
G10S - G10L
8. Screw the top plug onto the oil sump.
caution
Use Loctite 243 threadlocker or equivalents
Enclosure type
G05M - G05L
G06S - G06L
G07S - G07L
G08L
G10S - G10L
Mechanical seal sump
oil capacity (ml)
140
215
310
370
570
1800
Oil sump plug
1/8" NPT