Descargar Imprimir esta página

Ikegami ICD-879P Manual De Instrucciones página 27

Publicidad

Idiomas disponibles

Idiomas disponibles

5-4-10. Communication with control device (RS-485)
The camera can be controlled from a control terminal (PC, for example) or the
remote control unit provided by Ikegami, over RS-485 Link.
The RS-485 is the recommended standard by EIA for a serial data communication,
one class higher than RS-422 which is for Multi-drop connection, but the 485 is the
Multi-points connection type. Maxim communication speed is 10Mbps and normally
extendable up to 1,200 meters.(3,600 ft).
When you make RS-485 connection, make it sure to connect the right terminal as
there are plus and minus polarity, and also make sure to terminate at the last
machine in the link of daisy chain.
For details, refer to the Communications Specifications.
Example 1: With one camera being connected
RS-485 Termination
switch ON
Example 2: With four cameras being connected
RS-485 Termination
switch OFF
RS-485 Termination
switch OFF
RS-485 Termination
switch OFF
RS-485 Termination
switch ON
FOCUS LOCK
FOCUS LOCK
FOCUS LOCK
FOCUS LOCK
FOCUS LOCK
PC
Legend
PC
Automatic switcher
E-23
Monitor
Coaxial cable
RS-485 control cable
Monitor
Legend
Coaxial cable
RS-485 control cable

Publicidad

loading

Este manual también es adecuado para:

Icd-879