ENGLISH
5. CLEANING AND MAINTENANCE
-
Use only cleaning products specific for pressure washers.
-
The machine must be switched off and disconnected from the mains for cleaning or
maintenance.
-
Do not store the pressure washer outdoors or where it can freeze, the pump could be
severely damaged.
6. TROUBLESHOOTING
Problem
Smoke comes out of the
appliance.
There is not enough pressure.
The pressure washer does
not turn on.
Pressure fluctuates.
HYDROBOOST 2500 HOME&CAR
70
Cause
Overheating, overloading or
motor failure.
The inlet water filter is
clogged.
Air is entering from the hose
connections to the pump.
The nozzle or discharge valve
is worn or not the correct
size.
The unit is pressurised.
The plug is not properly
connected or the socket is
defective.
The extension cord is too long
or short.
The supply voltage is too low.
The thermal safety switch
has tripped.
The pump is sucking in air.
The nozzle is clogged.
The valves are dirty or worn.
Hydraulic seals are worn.
Solution
Turn off the device
immediately and contact the
Technical Support Service of
Cecotec.
Clean the inlet water filter.
Check that the connections
and the locking ring are tight.
Contact the official Technical
Support Service of Cecotec.
Press the gun trigger.
Check the plug,
the socket and fuses.
Remove the extension cord.
Make sure that the mains
voltage matches the voltage
stated on the rating label of
the appliance.
Switch off the device and
allow it to cool down.
Check that hoses and
connections are tight.
Clean them with the cleaning
clip.
Contact the official Technical
Support Service of Cecotec.