Descargar Imprimir esta página

Emos E8010 Manual De Instrucciones página 7

Estación meteorológica inalámbrica

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99
function. Once the signal is found, the icon will stop flashing (
time will be displayed. If no signal is detected, the DCF icon will not be shown.
To manually repeat the search for DCF signal, long-press the down arrow button. To cancel the
search, short-press the down arrow button again. DCF signal will be synchronised daily between
2:00 and 3:00 am.
During daylight saving time, the
Note: If the weather station detects DCF signal but the current time on the screen is incorrect (e.g.
shifted ±1 hour), you must set the correct time zone for the country where you are using the station,
see Manual Settings.
In standard conditions (at safe distance from sources of interference, such as TV sets or computer
monitors), the reception of time signal takes several minutes. If the weather station does not detect
the signal, follow these steps:
1. Move the weather station to another location and try to detect the DCF signal again.
2. Check the distance of the device from sources of interference (computer monitors or television
sets). The distance should be at least 1.5 to 2 m during the reception of signal.
3. When receiving DCF signal, do not place the weather station in the proximity of metal doors, win-
dow frames and other metal structures or objects (washing machines, dryers, refrigerators etc.).
4. DCF signal reception is weaker in reinforced concrete structures (cellars, high-rise buildings etc.),
depending on the conditions. In extreme cases, place the weather station close to a window in
the direction of a transmitter.
Reception of DCF radio signal is affected by the following factors:
• thick walls and insulation, basements and cellars;
• inadequate local geographical conditions (these are difficult to assess in advance);
• atmospheric disturbances, thunderstorms, electrical appliances with no interference elimination,
television sets and computers located near the DCF receiver.
Manual Settings
1. Long press the MODE button.
2. Then, repeatedly press the MODE button to choose settings for: year – month – day – calendar
language (DE, EN, DA, NE, IT, ES, FR) – 12/24h time format – hours – minutes – time zone –
forecast icon – pressure value – pressure unit.
Navigate between the values by pressing MODE, adjust settings using the up
Setting °C/°F Temperature Unit
Repeatedly pressing the °C/°F button switches temperature units.
Atmospheric Pressure – History
The pressure value is displayed in field no. 3.
Below the value is a chart of pressure history in, at most, the last 12 hours.
The chart is animated; this display method cannot be changed.
Moving the weather station to another place will affect the measured values.
Measurement will stabilise within 12 hours of battery insertion or relocation of the weather station.
Temperature/Humidity/Pressure Trends
Temperature, humidity and
pressure trend indicator
Moon Phase (see Fig. 4)
The moon phase is displayed in field no. 20.
1 – New moon
2 – Waxing crescent
3 – First quarter
4 – Waxing gibbous
icon will be displayed.
rising
5 – Full moon
6 – Waning gibbous
7 – Last quarter
8 – Waning crescent
7
stays on the screen) and current
and down
constant
arrows.
falling

Publicidad

loading