INSTALLATION AND CIRCUIT – Connecting the
Example 3
To add:
a 60-W GPS,
a 60-W radio,
a 120-W buzzer.
A
Hold fan
Radio
Depth-finder
GPS
Projector
Alarm system
Fridge
VHF
Some manufacturers indicate the intensity instead of the power consumed.
For direct current (the case here), simply multiply by 12 to obtain the
:
NOTE
power and divide the power by 12 to obtain the intensity the device
consumes.
IV -4-2-6-2Wiring:
① Choose a free fuse position,
 Connect the accessory power supply to the position terminal with a 6-mm female tab,
 If you must add a cable for connection, the minimum cross-section is 1.5 mm² and it must
comply with "marine" cable recommendations (UL1426 or SAE J378 or SAE J1127 or SAE
J1128 or, generally speaking, recommendations ABYC and/or CE),
 Connect the accessory grounding cable to the grounding terminal with a dia. 5 ring lug
(same remark as above for the cable),
 Use an ATO type fuse, max. intensity 15 A and with a higher operating intensity that the
accessory.
Options
and
60 W
60 W
��
120 W (< 180 W)
CONCLUSION
34 / 47
B
Miscellaneous lights
Miscellaneous
electronic equipment
Shower pump
Max. retained power
120 W (> 60 W)
��