JA: Set onboard alarm EOL resistor (Ra)
1 kΩ
4.7 kΩ (factory
default)
Off: No onboard alarm EOL.
JT: Set onboard tamper EOL resistor (Rt)
1 kΩ
4.7 kΩ (factory
default)
Off: No onboard tamper EOL.
JF: Set onboard fault EOL resistor (Rf)
2.2 kΩ
10 kΩ
Off: No onboard fault EOL (factory default).
J1: Set zone EOL mode
On: 3-resistor single zone.
Off: Isolated fault contact and 2-resistor zone.
Configuring the zone
To set up the zone, apply the following guidelines.
Select appropriate EOL resistor values with JA, JT and JF.
For example, setting of jumper JT determines Rt value.
For isolated outputs remove JT and J1.
Remove jumpers JA, JT and JF to exclude onboard EOL
values.
For dual resistor setting remove J1 and use terminal
3 and 6.
For a single zone with all onboard resistors set, the zone
resistance can be the following.
Table 2: Zone resistance values
Zone state
Value
0 Ω
Tamper (short)
Normal
Rt
Alarm
Rt+Ra
Fault
Rt+Rf
AM
Rt+Ra+Rf
Tamper (open)
P/N 466-5633-ML • REV D • ISS 19AUG22
2.2 kΩ
5.6 kΩ
2.2 kΩ
5.6 kΩ
3 kΩ
4.7 kΩ
Default
0 Ω
4.7 kΩ
9.4 kΩ
14.7 kΩ
19.4 kΩ
DIP switches
Table 3: SW1, general settings
Switch
Values
6: LED
On: LED on*
5: Remote
On: Remote on
4: Auto remote
On: Auto remote test
test
enabled
3: Polarity
On: Positive polarity
1, 2: Radar
1 On, 2 On: 16 m*
range
1 Off, 2 On: 14 m
*
Factory default
Table 4: SW2, AM settings
Switch
Values
4: AM signalling
On: AM to fault and
alarm relays*
3: Reset
On: Auto reset*
2: AM sensitivity
On: Advanced AM
sensitivity*
1: AM day/night mode
On: AM day mode
only*
*
Factory default
DIP switch SW1, general settings
SW1-1, SW1-2: Radar range
Use SW1-1 and SW1-2 to set the radar range exactly to fit the
application. The radar is of a range-gating type which means
that the range of detection is very accurate.
10 m
12 m
SW1-3: Polarity
On: Positive polarity. Configures the inputs (WT and D/N) as
"Active high".
Off: Negative polarity. Configures the inputs (WT and D/N) as
"Active low". Factory default.
The functionality is explained in Figure 9.
Figure 9
(1) Polarity high
(2) Polarity low
This function also depends on the SW1-5 setting. See "SW1-5:
Remote functionality" on page 6.
SW1-4: Auto remote test
On: Auto remote test on. Enables Auto remote test.
Off: Auto remote test off. Disables Auto remote test (factory
default).
If auto remote test is enabled, the control panel can trigger the
detector to perform a diagnostic test. This test is activated by
switching to walk test mode (day mode and WT enabled). The
detector activates the alarm relay if the test result is positive,
Off: LED off
Off: Remote off*
Off: Auto remote test
disabled*
Off: Negative polarity*
1 On, 2 Off: 12 m
1 Off, 2 Off: 10 m
Off: AM to fault relay
only
Off: Authorised reset
Off: Standard AM
sensitivity
Off: AM day and night
14 m
16 m
Factory default.
(3) Walk test
(4) Day/night
5 / 54