Walk testing the detector
There are two ways for switching on the walk test mode.
SW1-6 set to LED on, SW1-5 set to Remote off
In this mode the LED indication is always enabled (constant
walk test mode).
SW1-6 set to LED on, SW1-5 set to Remote on
This setting enables the walk test input (pin 7) and the
day/night input (pin 8). This allows the user to activate LED
indication remotely by setting the detector into the day mode
and activate the walk test.
Detector focusing
For the proper walk testing of the detectors, it is important to
have them focused.
Focusing can be achieved by not generating signals (not
moving) in a protected area for 20 s. This is not always
needed, however, when a hyperactivity or low activity is
noticed, the idle time before walk testing is recommended.
This allows you to simulate during walk testing a real scenario,
when the system is armed and nobody is present within the
protected area.
Green mode
When SW1-5 is set to Remote on, the radar is switched off
during the day mode (with no WT) to reduce current
consumption. The detector is then operating in PIR only mode.
Note:
The Day/night line must be connected to the control
panel for this mode to work.
This mode is not compliant with the EN 50131-2-4 standard.
Alarm memory
When SW1-5 is set to Remote on, alarms that occurred during
the night mode are stored in the detector memory. They are
indicated by flashing red LED when the unit switches to day
mode (walk test disabled). The memory is cleared when the
detector switches back to the night mode.
Note:
Set SW1-6 to Off to prevent showing the alarm memory
on the LEDs. See "SW1-6: LEDs" on page 6.
LEDs and outputs
To enable LEDs functionality, set SW1-6 to On, otherwise
LEDs are disabled in any condition. See "SW1-6: LEDs" on
page 6 for more details.
Table 6: LEDs and outputs
Status
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Microwave
intruder alarm
P/N 466-5633-ML • REV D • ISS 19AUG22
Alarm
Fault
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
voltage
Closed
Closed
Closed
Closed
Status
Red
Yellow
LED
LED
Dual motion
intruder alarm
Dual Alarm
Memory
AM alarm
Technical fault
Continuously ON
Normal blinking (1 Hz)
Specifications
Detector technology
Range
Viewing angle
PIR optics
Microwave frequency
Max microwave output at 1 m
Memory function
Input power
Peak-to-peak ripple immunity
Detector start-up time
Current consumption
Mounting height
Target speed range:
DDV1016AM-N
DDV1016AM-D-N
Alarm (NC) / Tamper relay
characteristic
Fault relay characteristic
Alarm time
Operating temperature
Relative humidity
Weight
Dimensions (H x W x D)
IP/IK rating
Pry-off tamper
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Alarm
Fault
To reset
relay
relay
Automatically
Open
Closed
after 3 s
Closed
Closed
Switch to the
night mode
Depends
Open
Depends on
on SW2-4
SW2-3
Closed
Open
Successful walk
test
Dual+AM
10, 12, 14, 16 m selectable via
SW1-1 and SW1-2
78 degrees
9 high-density mirror curtains
5.8 GHz
0.003 μW/cm²
Yes
9 to 15 V
(12 V nominal)
2 V (at 12 V )
60 s
10 to 22 mA (11 mA nom.)
2.0 to 3.0 m
0.2 to 3.0 m/s
0.1 to 4.0 m/s
80 mA 30 V , Form A
80 mA 30 V , Form A
3 s
−10 to +55°C
95% max., noncondensing
120 g
126 × 63 × 50 mm
IP30 IK04
Yes
7 / 54