5. Relieve the system pressure slowly, e.g. via the air shower
at the lung demand valve.
6. Residual pressure warning whistle must be triggered at
approx. 50 bar and be clearly audible.
7. After testing, prepare the product again according to the
chapter "Before use" (see chapter 4.2).
7
Transport and storage
Observe the temperature range (see chapter 10). Protect the
product against direct sunlight. All connections must be sealed
with dust caps. The high-pressure connector on the pressure
reducer unit must be closed with the enclosed dust cap. Store
the device in the supplied original packaging during longer
times of storage or transport.
8
Disposal
Disposing of the product generates different types of waste. A
distinction must be made between hazardous and non-
hazardous waste that must be disposed of in accordance with
local applicable regulations and guidelines.
9
Marking
WARNING
Do not remove or modify the safety markings on the product.
Damaged or missing safety markings should be replaced
immediately with markings matching the originals.
9.1
Name plate
The name plate is located on the product (sample illustration).
10
Technical data
Temperature range
-15 °C to +60 °C
Medium
Breathing air according to
DIN EN 12021
maximum permissible
300 bar
inlet pressure
Outlet pressure
6-8 bar
Cylinder coupling
G5/8 according to DIN EN 144-2
Plug-in coupling
extraction points
11
Order list
Description
CBS 1000 basic unit (mounting plate, pressure
reducer unit, extraction points)
Mask bag
Dust cap
O-ring (pressure reducer unit)
Sinter filter (pressure reducer unit)
Device cylinder 6.8 L/300 bar CRP
Device cylinder 9 L/300 bar CRP
PPE sets
1x Dräger X-plore® 4740 half mask (normal
pressure with RA threaded connection)
1x Dräger PSS® lung demand valve (LDV)
(normal pressure with RA threaded
connection)
1x Nomex mask bag
1x Dräger Panorama Nova® full face mask
(normal pressure with RA threaded
connection)
1x Dräger PSS® lung demand valve (LDV)
(normal pressure with RA threaded
connection)
1x Nomex mask bag
1x Dräger FPS® 7000 full face mask
(normal pressure with RA threaded
connection)
1x Dräger PSS® lung demand valve (LDV)
(normal pressure with RA threaded
connection)
1x Nomex mask bag
Transport and storage
Parker/Rectus 95 series
Cejn 341 series
Ordering
no.
6927200
6927208
R28498
D17409
3350746
3353733
3353734
6927210
6927211
6927213
en