GFCI Protector
DC Circuit Protector
DC CIRCUIT PROTECTOR
DC RECEPTACLE
DC Receptacle
The DC receptacle should ONLY be used for charging 12-volt automotive type batteries.
The DC charging output is not regulated.
DC Circuit Protector
The DC circuit protector automatically shuts off the DC battery charging circuit when
the DC charging circuit is overloaded, when there is a problem with the battery,
or when the connections between the battery and the generator are improper.
However, the circuit protector does not prevent overcharging.
Output Indicator
The output indicator (green) is illuminated when the generator is operating normally.
It indicates that the generator is producing electrical power at the receptacles.
AC RESET METHOD: ENGINE PAUSE
RESET
TEST GFCI MONTHLY
BUTTON
① START ENGINE.
② PUSH TEST BUTTON.
TEST
③ RESET BUTTON SHOULD POP OUT.
BUTTON
④ IF NORMAL OPERATION IS CONFRIMED.
PUSH RESET BUTTON IN.
⑤ IF GFCI FALLS THIS TEST.DO NOT USE
TAKE TO DEALER.
16