CONNECTION
Alternating Current (AC)
2
WARNING
• Be sure any electric devices are turned off before plugging them in.
NOTICE
Be sure all electric devices including the lines and plug connections are in good
condition before connection to the generato r.
Do not overload.The total load of all eletrical appliances must not exceed the
supply range of the generator. Overloading will damage the generator.
• Be sure the receptacle load current is within receptacle rated current.
When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer-based equipment or battery chargers, keep the
generator a sufficient distance away to prevent electrical interference from the
engine. Also ensure that electrical noise from the engine does not interfere with
any other electrical devices located near the generator.
If the generator is to supply medical equipment, advice should first be obtained
from the manufacturer, a medical professional or hospital.
Some electrical appliances or general-purpose electric motors have high
starting currents, and cannot therefore be used, even if they lie within the supply
ranges given in the above table. Consult the equipment manufacturer for further
advice.
The simultaneous usage of AC and DC power is possible but total wattage should
not exceed the rated output.
Generator rated output
Frequency
AC
DC
The overload indicator light
application range.
1
1.Start the engine.
2.Plug in to the AC receptacle.
3.Make sure the AC pilot light (Green) is on.
1
2
4.Turn on any electric devices.
Power factor
1.0
0.8
comes on when total wattage exceeds the
2
AC pilot light
Overload pilot light
2100W
2000W
1580W
96W
23
2600W
2500W
1980W
96W