4.Tighten the drain screw after clean the fuel.
5.Remove the spark plug, pour about one tablespoon of SAE 10W-30 or 20W-40
motor oil into the spark plug hole and install the spark plug. Recoil start the engine
by turning over several times (with ignition off) to coat the cylinder walls with oil.
6.Pull the recoil starter until you feel compression. Then stop pulling. (This prevents
the cylinder and valves from rusting).
7.Install the cover and tighten the screws.
8. Clean exterior of the generator and apply a rust inhibitor.
9. Store the generator in a dry, well-ventilated place, with the cover placed over it.
10. The generator must remain in a vertical position when stored, carried or operated.
TIP
If the cylinder was coated with oil during storage preparation, the
smoke briefly at startup. This is normal.
37
engine may