Possible voltage variants
3N AC 400 V, 50 Hz
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Circuit breaker trip characteristic
Minimum cross-section for connection cable
1N AC 230 V, 50 Hz
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Circuit breaker trip characteristic
Minimum cross-section for connection cable
Machine data
Machine width, total
Machine height, total
Machine depth, total
Niche width
Recommended wall spacing
Minimum wall distance
Packaging width
Packaging height
Packaging depth
Maximum gross volume
Maximum gross weight
Maximum net weight
Max. floor load in operation
Drum diameter
Diameter of drum opening
Drum depth
Drum volume
Diameter of door opening
Maximum door opening angle
Condensate drainage point on machine side (external diameter)
Emission sound pressure level
Sound power level
Average heat dissipation rate into the room
Permissible ambient temperature range
en - Technical data
Standard connection
3N AC 400 V
Standard connection
1N AC 230 V
1800 mm
10–40 °C
50 Hz
3,0 kW
3×16 A
Type B
2,5 mm²
50 Hz
3,0 kW
1×16 A
Type B
2,5 mm²
711 mm
1075 mm
1050 mm
1500 mm
500 mm
800 mm
1810 mm
1180 mm
1709 l
206 kg
193 kg
2052 N
685 mm
520 mm
569 mm
200 l
520 mm
180°
30 mm
55 dB (A)
66 dB (A)
2.3 MJ/h
21