Descargar Imprimir esta página

Ravaglioli KP 1396 E Traducción De Las Instrucciones Originales página 44

Elevador electro-hidraulico

Publicidad

9
9.2 PROBLEMS KP 1396 P - KP 1396 TP
PROBLEMS
The pump does not start
or stops during the
operation (before
reaching the maximum
pressure).
The pump works but does
not send oil
Low capacity
The pump does not reach
the maximum pressure.
The pump reaches the
maximum pressure but
does remain under
pressure.
Excessive oil leaks from
the air drainage.
Oil tank gets up to
pressure with air and oil
leaks from the valve.
Pump continues to pump
even after the pedal has
been released.
After a period of disuse,
the pump does not start.
The pawl release lever
does not disengage.
44
CAUSES
Return spring broken (25)
a)
b)
Air loss, check the piston seal (80)
a)
Oil level low
b)
Pump does not prime
a)
Tank not ventilated
b)
Insufficient air capacity
c)
Hydraulic causes:
- Check that the oil filter is not blocked
- Air in the hydraulic circuit
- Check that the ball (92) of the suction
valve works properly
a)
Check the air pressure
b)
Valve or gaskets faulty or dirty
Check hydraulic connections
a)
Dirt under the pedal
b)
The ball of the delivery valve
c)
Leakage on the apparatus connected
d)
a) Gaskets faulty
a)
Air leakage from the gaskets
b
Tank too full of oil
Gaskets faulty
a)
Air valve spring broken or too weak
b)
a) Gaskets faulty
a) Slackened connecting wire
0508-M001-3
REMEDIES
Replace
a)
b)
Replace if faulty
a)
Top up oil
b)
Operate the pedal in the "RELEASE
area at the same time as the air valve
to start the motor.
- Bleed the air out
- Pressurize the tank
CAUTION
Max. pressure 0.5 Bar (7 P.S.I.)
- Remove and clean
a)
Ventilate tank through the screw on the
plug (48)
b)
Capacity should be 250 Lt/minute
c)
- Clean or replace
- Bleed air from the circuit
- If necessary add a copper washer
(14) or replace coupling (15) if the
housing is worn.
a)
7 bar (100 P.S.I.) is required
b)
Clean or replace
Tighten if necessary
a)
Clean
b)
Replace gaskets
c)
Repair and check seal
d)
a) Replace
a)
Replace gaskets
b)
Check the level
Replace
a)
Replace
b)
a) Replace
a)
Adjust
KP 1396 TE - KP 1396 TP
KP1396 E - KP 1396 P
KP 1396 EACT

Publicidad

loading

Este manual también es adecuado para:

Kp 1396 pKp 1396 teKp 1396 tpKp 1396 eact