Descargar Imprimir esta página

Ravaglioli KPH-40ECGA Manual De Uso Y Mantenimiento página 22

Elevador de 2 columnas

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Trouble
Motor does not run.
Motor runs but will not
raise lift.
M o t o r r u n s — r a i s e s
unloaded lift but will not
raise vehicle.
Lift slowly settles down.
Slow lifting speed or oil
blowing out filler breather
cap.
Lift going up unlevel.
22
TROUBLE SHOOTING
Cause
Cause
1.Blown fuse or circuit breaker.
2.Incorrect voltage to motor.
3.Bad wiring connections.
4.Motor up switch burned out.
5.Overhead limit switch burned out.
6.Motor windings burned out.
1. Open lowering valve.
2. Pump sucking air.
3. Suction stub off pump.
4. Low oil level.
1. Debris in check valve seat.
2. Debris in lowering valve seat.
3. External oil leaks.
1.Air mixed with oil.
2.Air mixed with oil suction.
3.Oil return tube loose.
1.Equalizer cables out of adjustment.
2.Lift installed on unlevel floor.
1.Concrete floor thickness or holding
strength not sufficient.
0496-M004-0
Remady
1.Replace blown fuse or reset circuit
breaker.
2.Supply correct voltage to motor.
3.Repair and insulate all connections.
4.Replace switch.
5.Replace switch.
6.Replace motor.
1. Repair or replace lowering valve.
2. Tighten all suction line fittings.
3. Replace suction stub.
4. Fill tank to proper level with ISOVG32
Hydraulic Oil or Dexron III ATF.
1. Supply correct voltage to motor.
2. Clean lowering valve.
3. Replace relief valve cartridge.
4.Check vehicle weight and/or balance
vehicle weight on lift.
1.Clean check valve.
2.Clean lowering valve.
3.Repair external leaks.
1.Change oil using ISOVG32 Hydraulic
Oil or Dexron III ATF.
2.Tighten all suction line fittings.
3.Reinstall oil return tube.
1.Adjust equalizer cables to correct
tension.
2.Shim lift to level columns (Not to
exceed 1/2"). If over 1/2" break out
floor and repour per lift installation
instructions.
22

Publicidad

loading

Este manual también es adecuado para: