REPAIR ( CONTINUED )
Replace Power Switch
1.
Turn the pump OFF and disconnect from power.
2.
Remove the switch coverplate from the pump housing (see Figure 24).
3.
Remove the torx head screw, then remove the switch assembly
(see Figure 25).
4.
Unscrew both blade terminals and remove red pump wires from the
back of the switch (see Figure 26).
5.
Install a new switch by reversing the above procedure. Insert the switch
assembly into the pump cavity. Place the red wire between the circuit
breaker and the wall of the pump. Make sure the O-ring is seated
properly before tightening the switch coverplate.
NOTE: For the proper operation of the switch lever and cam, attach the
mounting plate to the switch with a clearance of 0.175 inch or about
3/16 inch (see Figure 27).
Figure 24
Figure 26
12
EN
Figure 25
Figure 27
Circuit
Torx
Breaker
Screw
0.175"