Baden
English
norms or by the laws in force in the country of installation. At any rate, always use
adequate equipment and clothing, such as: anti-injury boots, protection gloves,
spirit level.
For the installation, adhere to the following:
carefully examine the installation area, eliminating any danger to the operator;
Do not position the cabinet:
in environments where explosive gaseous substances are present;
in open air and therefore subjected to atmospheric agents;
near heat sources (direct sunlight, heating systems, incandescence lamps, etc.)
near air currents (near doors, windows, air-conditioning systems, etc.) that exceed
a speed of 0.2 m/sec.
Remove the supports in wood at the base (used for transport) and assemble the
adjustable feet (Rif. 8) positioning them so as to place the cabinet horizontally, aiding
yourself of a level (Rif. 10) to check proper alignment .
Before connecting the cabinet to the electrical line, make sure that the rating plate data
matches the characteristics of the electrical system to which the cabinet must be
attached.
For the unit to function properly, the temperature and relative humidity must not exceed
the limits for climate class 3 (+25°C; R.H. 60%) as established in EN-ISO 23953 - 2
regulations, under which the unit was tested
Multiplex up to 3 cabinets on the same electrical and refrigeration
supply line (1 master + 2 slaves)
If the cabinet is displaced, re-check its levelling; an incorrect levelling
compromises operation of the cabinet.
The cabinet must be levelled both at the front and at the back.
11.Electrical connection (Rif. 22) - specialized technician -
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
The electrical system must have a grounding connection!
The systems must be set up in accordance to the norms that regulate
manufacture, installation, use, and maintenance foreseen by the norms in
force in the country where the cabinet is installed.
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that stem from causes
directly ascribable to an electrical system malfunction.
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as the main line disconnecting switch.
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
performed in accordance to the power absorbed by the cabinet.
Remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
Consult the wiring diagrams before performing the connection.
Check that power supply voltage is the one reported on the rating plate.
Instruct the operator on the position of the switch so that it may be timely reached
in case of an EMERGENCY.
To ensure normal operation, the maximum variation of the voltage must range
between +/- 6% of the nominal value.
Check that the power supply line has wires with an appropriate diameter, that it is
protected against overcurrents, and that the leakages to ground are in compliance
26
.
05060141 00 05/03/2013