Descargar Imprimir esta página

Arneg BADEN 90 SELF Manual De Instalacion Y Uso página 28

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Baden
English
stopping the refrigeration cycle.
When the cabinet is defrosting, the temperature of the product on display will rise,
however, not above the limits established by law; when the defrosting cycle is over, the
system will rapidly return to its normal operating temperature.
15_1.Water drainage:
To evacuate the defrost water you must:
provide a drain to ground with a slight slope;
install the syphon supplied between the drain pipe of the cabinet and the
connection to ground.
hermetically seal the area of drainage to ground.
In this way, it is possible to avoid: bad odors inside the cabinet, dispersion of
refrigerated air, and the possible malfunction of the cabinet due to humidity.
Periodically check that hydraulic connections are perfectly efficient, contacting a
qualified installer.
16.Combining cabinets (Rif. 21)
To combine two or more cabinets in channel, proceed as follows:
1 - Disassemble the shoulders (if present).
2 - Position the cabinets side by side
3 - Join the risers and the brackets, using the screws supplied
CHANNEL COMBINATION KIT
Ref.
Code
1
04706025
2
01191113
3
04711065
4
04480112
5
04230600
6
04710037
7
02211300
17.Maintenance and cleaning - - qualified operator -
The food products can rotten due to microbes and bacteria. Compliance to the hygiene
norms is essential to safeguard the health of the consumer, in addition to compliance to
the cold chain, of which the sales area represents the last ring that can be monitored.
The cleaning operations must include:
4 - WASH (roughing, removal of approximately 97% of the dirt)
5 - DISINFECTION (deterge the surfaces to eliminate pathogenic micro-organisms that
have remained after the wash).
6 - RINSING
7 - DRYING
Cleaning of the refrigerated cabinets is divided as follows:
17_1.General instructions
BEFORE STARTING TO CLEAN THE CABINET, DISCONNECT THE
ELECTRIC POWER SUPPLY VIA THE MASTER SWITCH
Before any operation, wait for the glass parts to have reached room
temperature.
Protect the hands with work gloves.
The surface to be cleaned, the water and detergents used to clean it
must not have a temperature higher than 30°C, therefore, do NOT use
hot water on the cold glass of the surfaces, as it could break and harm
the operator.
28
TSP M4x8 IX screw
Shelf junction plate
TCEI M8X120 screw (Hexagon Socket Head Cap Screw)
Washer D 8.5x24
Hex Nut M8
Screw TCEI M8x60
Cabinet junction bracket
Description
05060141 00 05/03/2013

Publicidad

loading

Este manual también es adecuado para:

Baden 90Baden 90 ckBaden 90 h125Baden 90 h110