SeTTing The firST remoTe conTrol
This operation can only be performed when the motor is new, or after a total delete of
the memory.
T1: First remote control to be set.
A
+
B
T1
adJuSTmenT of The limiT SwiTcheS
Blue wave RX tubular motors have an electronic limit switch encoder-system. This system
ensures great reliability and precision in keeping the positions. Limit switch regulation is
performed simply with the remote control. During setting, the motor moves only as long
as the up or down button is pressed, stopping when the button is released. At the end of
regulation, press either the up or down button briefly to move the motor.
After setting the remote control, it's necessary to set first the closing position!
For cassette-awnings, hold the button pressed until the motor stops automatically on the
closing position. For open awnings, hold the button pressed and drive until the necessary
closing position.
notes: - If the awning is completely closed, you have firstly to open it by around 20 cm.
- Because the correct rotation direction will be identified only after the closing
position is set, to close the awning, during setting the closing position, it's
sometimes necessary to use the "down" button.
To set the closing position, hold pressed the "stop" button (around 2 sec) until the motor
performs a short "down" movement.
Tn: Already programmed remote control
A
C
During this step, power up only one motor at time!
SeTTing The cloSing poSiTion
?
Tn
up
B
T1
B
Tn (2 sec)
30
B
T1 (2 sec)