ShorT-Term SeTTing of a remoTe conTrol
This function makes it possible to store a remote control temporarily, for example, with
the purpose of setting the limit switches during assembly in the factory. A later fi nal
saving of the remote control will be possible using the appropriate command sequence
(see: "SETTInG THE FIRST REmOTE COnTROL"). The operations described below can be
carried out only when the motor has just come out of the factory or after a full memory
clearing (see: "FULL mEmORy CLEARInG"). The motor makes the following operations
possible only within the time limits described in order to make sure that the short-term
setting is used only in the installation or factory setting phase and not during daily use.
power up the motor, make sure that no other motors having an empty memory are
powered up in the same operating range.
within 30 seconds after start, press the B and C buttons simultaneously until the
motor gives a confi rmation signal.
The remote control will remain stored for 5 minutes, while the motor is powered up.
After 5 minutes or when no voltage is supplied to the motor, the remote control will be
cancelled.
T1: remote control to be stored
B
C
+
T1
38