Descargar Imprimir esta página

BFT VIRGO Instrucciones De Instalación página 35

Automatizaciones a brazo para portones con batiente
Ocultar thumbs Ver también para VIRGO:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Parameter
min.
max.
1
99
OP. F ORCE
1
99
CLS. F ORCE
15
99
OP SPEED
15
99
CL SPEED
SLOW SPEED
15
99
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
Step-by-step
STEP-BY-STEP
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Block pulses during
IBL OPEN
opening
Closing limit switch
PRESS SWC
pressure
1 motor active
1 MOT. O N
Reversal of the
change mot
motor time lag
Open in other
OPEN IN OTHER
direction
DIRECT.
INSTALLATION MANUAL
Default
Personal
Definition
Leaf force during
50
opening [%]
Leaf force during
50
closing [%]
99
Opening speed [%}
99
Closing speed [%]
25
Slow-down speed [%]
Cross out
Default
setting
used
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
0
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
0
limit switch must be adjusted accurately (Fig.R Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor inter-
0
preting this as an obstacle.
1
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the
mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing
limit switches to trip slightly earlier (Fig.R Ref.A).
0
Both motors active (2 leaves).
0
1
Only motor 1 active (1 leaf ).
Opening: M1 starts in advance in comparison with M2 (opening time lag). (See Fig. L)
0
Closing: M2 starts in advance in comparison with M1 (closing time lag). (See Fig. L)
The pedestrian operation is performed by M1
0
Opening: M2 starts in advance in comparison with M1 (opening time lag). (See Fig. L)
1
Closing: M1 starts in advance in comparison with M2 (closing time lag). (See Fig. L)
The pedestrian operation is performed by M2
0
Standard operating mode (See Fig.L).
0
1
Opens in other direction to standard operating mode (See Fig. L)
Description
Force exerted by leaf/leaves during opening. This is the percentage of
force delivered, beyond the force stored during the autoset cycle (and
subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of
force delivered, beyond the force stored during the autoset cycle (and
subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during
opening. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during
closing. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a
percentage of maximum running speed. WARNING: Once the parameter
has been edited, a complete uninterrupted opening-closing cycle is
required. WARNING: When the display reads ""SET"", obstacle detection
is not active.
Optional extras
2 STEP
CLOSED
OPENS
DURING
CLOSING
OPEN
CLOSES
DURING
OPENING
AFTER STOP
OPENS
step-by-step mov.
3 STEP
4 STEP
OPENS
OPENS
STOPS
CLOSES
CLOSES
STOP + TCA STOP + TCA
OPENS
OPENS
VIRGO
- 35

Publicidad

loading