OPERATION
Remove the laser from its carrying case. The instrument is shipped with a battery current
protection insert, which must be removed before operation.
NOTE: All ALH and ALHV(-G) instruments are shipped with ADS on as the default setting. This
setting can be changed by the user (see Anti-Drift System - ADS, page 16).
NOTE: ALGR instruments will default to Grade Mode when the instrument is turned on. The Mode
button is used for both selecting between the X-axis and Y-axis for setting grade and exiting
the Grade Mode (see Grade Mode — Dual or Single Axis Grade). Press and release the
Mode button to select between the X-axis and Y-axis when setting grade. To exit the Grade
Mode, press and hold the Mode button for 4 to 5 seconds, then release. This will bring up
the Mode Select Menu. The user can now toggle to other menu options. Pressing the Mode
button for 4 to 5 seconds and releasing is only required to exit the Grade Mode.
Leveling
1:
The instrument can stand alone on a level, sturdy surface or preferably secured to a 5⁄8-11
surveyor's tripod.
2:
Press the (A) button once, and allow time (up to 60 seconds) for the instrument to self-level.
NOTE: The laser head may begin to rotate before leveling is complete. The self-leveling speed is
approximately 1° per 4 seconds.
3:
After self-leveling, the instrument will begin operating in Rotation Mode.
NOTE: The ALHV,ALHV-G will return to last mode of operation (i.e. sweep, spot, or rotation speed);
however, does not retain grade information.
NOTE: After self-leveling, the instrument will begin operating in Rotation Mode for ALH, last selected
mode of operation (i.e. Sweep, Spot, Rotation Mode) for ALHV, ALHV-G, and Grade Mode
for ALGR.
Cross Axis Leveling (Models ALHV, ALHV-G)
NOTE: ADS must be off to enable cross-axis leveling.
1.
Press the Manual mode (C) button once to enable cross-axis leveling. The instrument will level in
the x-axis only. The manual grade can be set in the y-axis only.
2.
Press the Manual mode (C) button again to shut off the cross-axis leveling and to place the
instrument into Manual mode.
NOTE: When the ADS is off, the remote Mode button will place the instrument in cross-axis leveling
with the first press and in Manual mode with the second press.
Plumbing / Lay-Down (Models ALHV, and ALHV-G)
1.
On a flat surface, place the instrument on its back using the built-in trivet (control panel
facing upward). (Fig. 7)
2.
Press the (A) button once, and allow time for the instrument to self-level.
NOTE:When the Instrument is placed in the laydown position, the ADS button (B) becomes the
Auto Beam Positioning button.
AL-SERIES • 13