8. FAQ's(Frequently Asked Ques tions)
7. It is not possible to set the high and low temperatures separately – both are adjusted
at the same time (Raising one, raises the other as well, etc.).
This is normal: The temperature setting for the LOWER ZONE should always be the same or
higher than the UPPER ZONE. So, when the user adjusts the temperature of one of the zones,
if the above condition is not met, the temperature setting of the second zone will change
automatically to conform to the conditions.
8.
It seems that the control panel is not working.
The control panel of this appliance has auto-locking, to avoid undesired manipulation of the
settings. This is automatically activated 2 minutes after the control panel is left untouched. To
unlock the control panel, press UP and DOWN keys together for 5 seconds.
The fans are constantly working. Is this is normal?
9.
To circulate air and maintain the set temperature inside the cabinet, the interior fans will turn
ON and OFF when the compressor is on in Dynamic Climate mode. The fan will turn on and
off every 20 seconds, approximately. This is normal and serves to circulate air as well as to
ensure the operating status of the fans. Fans working continuously. If the fan stops compete,
and does not complete the cycle, the fan is not working.
10. The digital screen works. But the unit is not cooling.
Check to see if the unit is in "Demo Eco mode". Simultaneously press "UP", "DOWN" and
"LIGHT" at the same time for at least 5 seconds to exit Demo Eco mode.
11. The digital screen, the light and the sound do not work, but the unit is cooling well .
Perhaps the unit is in "display OFF" mode
12. Ice is building up at the bottom rear (compressor area) obstructing the fan and
causing the unit to malfunction.
Check that the lower part or in the vicinity, especially in built-in models, there is another
appliance producing heat, such as a freezer, oven, etc., THE COOLER SHOULD NOT BE
PLACED IN THESE LOCATIONS.
135