n Tank Inspection
The life of an air receiver tank is dependent upon several factors including, but
not limited to, operating conditions, ambient environments, and the level of
maintenance. The exact effect of these factors on tank life is difficult to predict;
therefore, Ingersoll Rand recommends that you schedule a certified tank
inspection within the first five years of compressor service. To arrange a tank
inspection, contact the nearest Ingersoll Rand service provider.
If the tank has not been inspected within the first 10 years of compressor service,
the tank must be taken out of service until it has passed inspection. Tanks that
fail to meet requirements must be replaced.
WARNING
l Failure to replace a rusted air receiver tank could result in air receiver
tank rupture or explosion, which could cause substantial property
damage, severe personal injury, or death. Never modify or repair tank.
Obtain replacement from service center.