WEG WECM / Emerald eZA 14634998 Manual De Instalación, Operación Y Mantenimiento página 27

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5 - INSTALLATION
DANGER!
 Make sure the AC power supply is disconnected and protected against accidental
energization before starting the installation;
 Check the motor direction of rotation, turning it without load before it is coupled
to the load;
 To prevent accidents, ensure that the grounding connection has been performed
according to the applicable standards and that the shaft key has been securely
fastened before the motor is started;
 Do not lift and/or carry the product holding by the input cables.
Motors must be only installed in places compatible with their mounting features and in applications
and environments for which they are intended.
Those motors with feet must be installed on bases duly planned in order to prevent vibrations and
assure perfect alignment. The motor shaft must be properly aligned with the shaft of the driven
machine. Incorrect alignment, as well as improper belt tension, will certainly damage the bearings,
resulting in excessive vibrations and even causing the shaft to rupture. The admissible shaft radial
and axial loads for standard bearings are specified on the table below. Use flexible coupling whenever
possible.
Allowed loads for Emerald eZA (NEMA 48) motors:
Direction
Axial*
Radial**
Maximum permissible thrust - Fr in (kN) 26280 hours
Mounting position
Horizontal
Vertical shaft down
Vertical shaft up
All
Type
Pushing
Pulling
Pushing
Pulling
Pushing
Pulling
L
L/2
WECM / Emerald eZA Manual | 27
www.weg.net
1800rpm
Force (kN)
0,27
0,14
0,32
0,11
0,24
0,19
0,11
0,20

Publicidad

Tabla de contenido
loading

Tabla de contenido