CP 0020
♦
Change damaged parts immediately.
Replace damaged and worn components in good
♦
time.
Make sure that all the attached and related
♦
equipment, such as hoses, water separators, and
lubricators are properly maintained.
Periodic maintenance
Since each application differs, the frequency and
extent of maintenance is best established based upon
past performance. Keeping detailed maintenance
records of past performance, aids determining future
preventative maintenance intervals.
Periodic maintenance
Time interval, pump hour
Check
Check
Every
point
concerns
Hoses and
Leakage,
connections
damage
Inlet filter
Clogging,
damage
Threaded
Tightness
unions
Pump,
-
complete
Oiler
Oil level,
function
In the event of breakdown or worsening pump
performance, establish the cause and rectify the fault.
Ideally, repairs should be carried out in a workshop.
9800 1056 90a | Original instructions
Every
Every
8th
40th
400th
X
X
X
X
X
Safety and operating instructions
Tightening torques
A.
Valve, 30-40 Nm
B.
Air inlet bushing, 120-140 Nm
Nut, 275-300 Nm
C.
Screw, 25-30 Nm
D.
E.
Handle, 30-40 Nm
13