5 - SYSTEM CUSTOMISATION
5 - PERSONALIZZAZIONE DELL'IMPIANTO
The configuration menus of the equipment operating functions are divided into BASE and ADV (basic/advanced). The following tables
show the description of each basic parameter with the respective minimum, maximum and default values.
1. Press and hold the button
access the basic menu.
2. Scroll through the menu items with the buttons
3. Press and hold the button
4. To change the value, use the buttons
(MENU) until the display stops flashing
5. To exit the menu, briefly press the button
NOTE: to view the value of any parameter simply enter the relevant menu (BASE or ADV) using steps 1 and 2 of the procedure just
described. Once the desired parameter has been identified, the display alternately shows the name of the parameter and the value.
To exit the menu, briefly press the button
5.1 - Basic Parameters
PARAMETERS
1
2
3
4
5
6
7
8
14
(MENU); the display shows in sequence
(UP) and
(MENU) until the display flashes; release the button
(UP) and
(MENU)
(MENU)
DESCRIPTION
Automatic re-closing time (0 = off)
Re-closing time after the transit on PH1 (0 = off)
Force on obstacles
0 = Maximum impact force
10 = Minimum impact force
Motor speed in opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
Motor speed in opening during the slowing down phase.
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
Motor speed in closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
Motor speed in closing during the slowing down phase.
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
STEP-By-STEP or SBS configuration:
0 = Normal (-ST-CH-ST-AP-ST...)
1 = Alternate (-ST-CH-AP-ST-CH...)
2 = Alternate (AP-CH-AP-CH...)
3 = Condominium – timer (set
4 = Condominium with immediate re-closing
and
(DOWN-RADIO) until reaching the desired parameter
(DOWN-RADIO) ; to confirm the new value press and hold the button
≠ 0)
, release the button at the wording
(MENU)
DEFAULT
MIN
MAX
0
0
900
0
0
3
0
4
1
1
1
4
1
1
1
0
0
to
UNIT
s
30
s
10
5
5
5
5
4