6 - TESTING AND COMMISSIONING THE AUTOMATION SYSTEM
The system must be tested by a qualified technician, who must
perform the tests required by the relevant standards in relation to
the risks present, to check that the installation complies with the
6.1 - Testing
All system components must be tested following the procedures de-
scribed in their respective operator's manuals;
ensure that the recommendations in Chapter 1 - Safety Warnings -
have been complied with;
check that the gate or door is able to move freely once the automa-
tion system has been released and is well balanced, meaning that it
will remain stationery when released in any position;
check that all connected devices (photocells, safety edges, emer-
6.2 - Commissioning
Once all (and not just some) of the system devices have passed the
testing procedure, the system can be commissioned;
the system's technical dossier must be produced and kept for 10
years. It must contain the electrical wiring diagram, a drawing or
photograph of the system, the analysis of the risks and the solutions
adopted to deal with them, the manufacturer's declaration of con-
formity for all connected devices, the operator's manual for every
device and the system maintenance plan;
fix a dataplate with the details of the automation, the name of the
person who commissioned it, the serial number and year of con-
struction and the CE marking on the gate or door;
also fit a sign specifying the procedure for releasing the system by
hand;
Enabling of continuous flashing for assistance request
with
≠ 0 (function only performed
when the gate is closed).
0 = disabled
1 = enabled
Electric lock activation time if the electric lock is activated.
Deactivation time of the magnetic electric lock if the
magnetic lock is selected.
High speed motor start
0 = disabled
1 = activated
Shows the type of encoder in use
0 = disabled (virtual encoder)
1 = activated (physical encoder)
Determines the type of automation on which the control
unit is installed:
0 = Reset to factory settings for TU4324/TUS4324 sliding
motor
1 = Factory reset for SUN5324 sliding motor
2 = Factory reset for sliding motor SUN7324, TU7324/
TUS7324
3 = Factory reset for sliding motor SUN11324M,
TU11324/TUS11324
4 = Restore factory settings for 4/6 m barrier (see the
user manual for the barrier)
5 = Restore factory settings for 8 m barrier (see the user
manual for the barrier)
6 = Restore factory settings for overhead door
0
4
0
0
1
relevant regulatory requirements, especially the EN 12453 standard
which specifies the test methods for gate and door automation sy-
stems.
gency buttons, etc.) are operating correctly by performing gate or
door opening, closing and stop tests using the connected control
devices (transmitters, buttons or switches);
perform the impact measurements as required by the EN12453
standard, adjusting the control unit's speed, motor force and de-
celeration functions if the measurements do not give the required
results, until the correct setting is obtained.
draw up the declaration of conformity, the instructions and precau-
tions for use for the end user and the system maintenance plan and
consign them to the end user;
ensure that the user has fully understood how to operate the system
in automatic, manual and emergency modes;
the end user must also be informed in writing about any risks and
hazards still present;
!
WARNING
after detecting an obstacle, the gate or door
stops during its opening travel and automatic closure is disabled;
to restart operation, the user must press the control button or use
the transmitter.
0
1
1
10
s
0
1
0
1
0
6