ELECTRICAL CONNECTIONS
FOR ENERGY SAVING
POWER SUPPLY
POWER
SUPPLY
1
2
1 2
3 4
GND
12/24
COM OUT
_
GND
12/24
_
AC/DC
AC/DC
NC
1
2
TX
RX
PH2
GND
12/24
_
AC/DC
WARNING !
To enable
paragraph 5.1, point 12. Only during this function
PHOTOTEST is not possible
SAFETY AND CONTROL DEVICE CONNECTORS
24 VAC
Accessory power supply 24VAC non-regulated 200mA MAX; not active during battery operation
24 VAC
COM
Common positive for FLASH - IND/ELEC - LED and accessories outputs
IND, gate open warning light output, 24VDC 5W MAX
IND/ELEC
ELEC, electric lock output 12VDC 15VA MAX
selectable with the
LED
Courtesy light output, 24VDC non-regulated 15W MAX also controllable via radio remote control
NEG
Negative power supply for accessories
Positive power supply for PH1 and PH2 photocells;
PH-POW
operating mode configurable with the
EDGE
8k2/NC safety edge contact input; operating mode configurable with the
EDGE
WARNING !
PH2 opening photocell NC input; at any time during opening/closing, the intervention of the photocell (opening of the
contact) causes the movement to immediately stop. Closing the contact restores the opening operation. The operating
PH2
modes can be configured with the
WARNING !
PH1 closing photocell NC input; at any time during closing, the intervention of the photocell (opening of the contact)
causes blocking and reversal of the direction of travel. While PH1 is active it is not possible to close the gate. The
PH1
operating modes can be configured via the
WARNING !
NO OPENING command input; MAN PRESENT function configurable with the
OPEN
5.2, point 16)
CLOSE
NO CLOSING command input; MAN PRESENT function configurable with the
NO PARTIAL OPENING command input, also configurable as a second safety edge/STOP via
PAR
With the
MAN PRESENT function configurable with the
NO STEP-BY-STEP command input (SBS); upon each activation the commands AP (open) - ST (stop) - CH (close) are
SBS
executed in succession; the operating modes are configurable with the SBS SETUP parameter.
MAN PRESENT function configurable with the
COM
Common positive inputs PH2, PH1, OPEN, CLOSE, PAR, SBS
SHIELD
Antenna - shield
ANT
Antenna - signal
8
1 2
3 4
GND
12/24
COM OUT
_
AC/DC
NC
TX
RX
PH1
see
parameter (paragraph 5.2, point 17)
with the
dip switch in the ON position the input is always disabled
with the PH2 dip switch in the ON position the input is always disabled
with the PH1 dip switch in the ON position the input is always disabled
parameter the input can be configured as a second safety edge (paragraph 5.1, point 9)
ELECTRICAL CONNECTIONS FOR PHOTO1 AND PHOTO2
PH2
PH2
TX
RX
1
2
parameter (paragraph 5.2, point 3)
parameter (paragraph 5.2, point 2)
parameter (paragraph 5.2, point 1)
parameter
parameter
PH1
PH1
TX
RX
1
2
parameter (paragraph 5.2, point 4)
parameter (paragraph
parameter
parameter;