9
10
11
12
5.2 - Advanced Parameters
The ADVANCED MENU allows the system to be further customi-
sed by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU key and
hold it down for 5 seconds.
PARAMETERS
foto1 setup
1
foto2 setup
2
photo test
3
type edge
4
Additional insertion/additional edge:
0 = disabled
1 = the PAR input becomes STOP NO
2 = the PAR input becomes STOP NC
3 = the PAR input becomes EDGE NC on opening
4 = the PAR input becomes EDGE 8K2 on opening
5 = the PAR input becomes EDGE 4K1 on opening
!
WARNING
to activate EDGE2, the TYPE EDGE
parameter must be 0 (EDGE1 only on closing)
!
WARNING
EDGE2 is connected as "Opening Edge"
and will be considered if it is engaged during the opening. It
will react with a short gate reverse to clear the obstacle.
!
WARNING
deactivation of the safety with DIP
SWITCH has no effect on this input.
Slowdown amplitude
P = customised by learning
From 1 to 100 = Percentage of slowdown in closing and opening
of the motors
Behaviour after power failure
0 = no action, it remains as it is
1 = Closure
Energy saving: enabling to turn off the photocells when the gate
is closed (only during this function the PHOTOTEST is not pos-
sible)
0= disabled
1= enabled
DESCRIPTION
PHOTO1 behaviour when starting from closed
0 = Check PHOTO1
1 = The gate opens even with PHOTO1 engaged
Use of PHOTO2:
0 = Enabled both during opening and closing
1 = Enabled only during opening
2 = If it exceeds, it turns on the courtesy light for a time
TIME LIGHT
set by the "
" parameter (sliding door only)
Photocell functionality test:
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
STOP/EDGE input selection:
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Safety contact edge (NC)
3 = Double resistive safety edge (4k1)
When an edge is activated, the automation performs a
brief reversal and then stops.
0
20
0
0
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
NOTE: Some default functions/displays may vary depending
on the type of motor selected.
DEFAULT
1
1
0
1
0
5
1
100
%
0
1
0
1
MIN
MAX
UNIT
0
1
0
2
0
3
0
3
EN
15

Publicidad

loading