Installing the air discharge hose
Place the appliance near a window or opening, so that the air can flow to the outside
via the discharge hose.
1. Carefully pull out the discharge hose until the required length is achieved.
2. Screw an end of the discharge hose (B) in the square connector (A).
3. Screw the round connector (C) on the other end of the discharge hose (B).
4. Slide the square connector (A) at the rear of the air conditioner on the air outlet.
5. Hang the other end of the discharge hose (B) to the outside. Ensure a free
passage of the hose. Close the window and door as much as possible. If
necessary, use the window seal plate.
6. REMARK: Optimum operation of the air conditioner depends on the length of the
discharge hose and the number of bends. Try to limit both. The supplied flexible
discharge hose has a maximum length of approx. 150 cm and corresponds with
the capacity of the air conditioner. The use of any other hoses or extensions
could cause failures in the appliance. The air should be able to flow without any
hindrance, or else this could cause overheating of the appliance or condensation
of water in the air discharge hose. Therefore make sure there are no kinks or
sharp bends in the discharge hose. For an optimum result, the discharge hose
should be kept shorter than 1 meter during use of the air conditioner.