Descargar Imprimir esta página

Titan ELITE 2000 Instrucciones De Uso página 14

Airless equipo de alta presión para pulverizar

Publicidad

Idiomas disponibles

Idiomas disponibles

INTERRUPTION OF WORK / CLEANING THE UNIT
7
INTERRUPTION OF WORK
1. Set pressure relief valve to
Switch the pump OFF using the ON/OFF switch (Pos. 0).
2. Pull trigger of the spray gun to decrease the pressure of
the high pressure hose and the spray gun.
3. Secure the spray gun trigger, refer to the operating manual
of the spray gun.
4. Remove tip from tip holder and store the tip in a small
vessel with suitable cleaning agent.
5. Leave the suction system immersed in the coating material
or immerse it in the corresponding cleaning agent. The
suction filter and unit should not dry out.
6. Cover the material container in order to prevent the paint
from drying.
In using quick-drying or two-component coating
i
materials, do not fail to rinse unit through with
a suitable cleaning agent during the processing
period.
8
CLEANING THE UNIT
A clean state is the best method of ensuring operation without
problems. After you have finished spraying, clean the unit.
Under no circumstances should coating material dry and
harden in the unit. The cleaning agent used for cleaning (only
with a flash point above 100˚F (38 °C) must be suitable for the
coating material used.
Warm water improves the cleaning effect in the
i
case of water-dilutable coating materials.
Secure the spray gun, refer to the operating manual of the
spray gun.
Remove and clean the tip and tip holder.
UNIT WITH SUCTION SYSTEM
1. Set pressure relief valve to
2. Switch the pump ON (Pos. I) using the ON/OFF switch.
3. Remove the suction system from the material container.
The return pipe hose remains over the material container
until barely any coating material comes out.
4. Immerse the suction system into a container filled with a
suitable cleaning agent
5. Turn the pressure control valve back in order to set a
minimal spraying pressure.
14
(pressure relief, circulation).
(circulation).
6. Set pressure relief valve to
7. Pull the trigger of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container (if
appropriate, increase the pressure at the pressure control
valve slowly in order to obtain a higher material flow).
The container must be grounded in case of
coating materials which contain solvents (e.g. by
using a metal container).
Caution! Do not pump or spray in container with
small opening (bunghole)!
See safety regulations.
8. Set pressure relief valve to
9. Pump suitable cleaning agent in the circuit for several
minutes.
The cleaning effect is increased by alternatively
i
opening and closing the spray gun.
10. Set pressure relief valve to
11. Pump the remaining cleaning agent into an open container
until the pump is empty.
For long-term, cold weather storage, or any
i
freezing temperature exposure pump mineral
spirits through the entire system.
For short-term storage not exposed to freezing
temperatures when using latex paint, pump
water mixed with Titan Liquid Shield through
the entire system (see Accessories section of this
manual for part number and product label for
dilution instructions).
13. Set pressure relief valve to
14. Switch the pump OFF using the ON/OFF switch (Pos. 0).
UNIT WITH OPTIONAL HOPPER
1. Set pressure relief valve to
2. Switch the pump ON (Pos. I) using the ON/OFF switch.
3. Turn the pressure control valve back in order to set a
minimal spraying pressure.
4. Set pressure relief valve to
ELITE 2000
(spray).
(circulation).
(spray).
(circulation).
(circulation).
(spray).

Publicidad