Descargar Imprimir esta página

Titan ELITE 2000 Instrucciones De Uso página 3

Airless equipo de alta presión para pulverizar

Publicidad

Idiomas disponibles

Idiomas disponibles

ELITE 2000
1.2
GROUNDING INSTRUCTIONS
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING - Improper installation of the
grounding plug can result in a risk of electric
shock.
If repair or replacement of the cord or plug is necessary, do not
connect the green grounding wire to either flat blade terminal.
The wire with insulation having a green outer surface with
or without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualified electrician or serviceman if the grounding
instructions are not completely understood, or if you are in
doubt as to whether the product is properly grounded. Do not
modify the plug provided. If the plug will not fit the outlet,
have the proper outlet installed by a qualified electrician.
This product is for use on a nominal 120 volt circuit and has a
grounding plug that looks like the plug illustrated below. Make
sure that the product is connected to an outlet having the same
configuration as the plug. No adapter should be used with this
product.
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
When the sprayer is used with a generator or
uncontrolled line voltage, the use of Titan's "Line
Surge Protector" (P/N 800-935) is recommended.
Attention
IMPORTANT ELECTRICAL INFORMATION
Use only a 3-wire extension cord that has a
3-blade grounding plug and a 3-slot receptacle
that will accept the plug on the product.
Attention
Make sure your extension cord is in good condition. When
using an extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized cord
will cause a drop in line voltage resulting in loss of power and
overheating.
A 12 or 14 gauge cord is recommended (see chart). If an
extension cord is to be used outdoors, it must be marked with
"SJW" or "SJTW". For example, a designation of SJTW would
indicate that the cord would be appropriate for outdoor use.
Cord gauge
12
14
1.3
SAFETY HAZARDS
WARNING: INJECTION INJURY
A high pressure stream produced by this
equipment can pierce the skin and underlying
tissues, leading to serious injury and possible
amputation.
Do not treat a spraying injury as a harmless cut. In
case of injury to the skin through coating materials
or solvents, consult a doctor immediately for
quick and expert treatment. Inform the doctor
about the coating material or solvent used.
PREVENTION:
Do not aim the gun at, or spray any person or animal.
Keep hands and other body parts away from the discharge.
For example, do not try to stop leaks with any part of the
body.
NEVER put your hand in front of the gun. Gloves will not
provide protection against an injection injury.
ALWAYS keep the tip guard in place while spraying. The tip
guard provides some protection but is mainly a warning
device.
Only use a nozzle tip specified by the manufacturer.
SAFETY PRECAUTIONS
Maximum cord length
150 feet
100 feet
3

Publicidad

loading