English
Align the bottom unit
Align the stand: Position the unit and
n
check the alignment with a spirit level
in the cooking cabinet. If necessary,
align the castors or feet evenly so that
the unit is standing securely.
Align the levelling kit: Align the level-
n
ling kit and check the alignment with a
spirit level before positioning the
lower unit on the levelling kit.
5
Installation
Setting up the Combi-Duo and the top unit
NOTICE
Mounting and attachment of the top
unit on the top base plate
The top unit is attached to the top base
plate with only three screws. The fourth
attachment is difficult to access through
the cover for flue pipes and is not
absolutely necessary.
a
The bottom unit is placed on a stand
with feet or castors or an auto levelling
kit.
a
The top side of the bottom unit is
clean and free of grease.
1. Loosen 3 screws from the lid of the
bottom unit [
2. Place the Combi-Duo base plate on
the lower unit. Align the base plate so
that the closed, right side panel is flush
with the right unit wall.
3. Secure the Combi-Duo base plate with
3 screws [
Photo
4. Install the feet on the base plate with
cap nuts [
Photo
5. Mount the holder on the bottom side
of the top base plate [
14 / 96
Photo
02].
03].
04].
Photo
05].
80.51.378_iCombiPro-iCombiClassic_CD-U_IM_EU-west
6. Attach the top base plate to the feet
[
Photo
06].
Top unit: 6-1/1 - 10-2/1
1. Remove the rubber seal around the
unit feet edges of the top unit
[
Photo
07].
2. Place the top unit carefully on the
Combi-Duo intermediate assembly kit
[
Figure
08].
3. Secure the top unit base plate of the
Combi-Duo Intermediate Assembly Kit
with at least 3 screws [
4. Install the rubber seal around the bot-
tom edge of the top unit
[
Photo
10].
5. If an Ethernet cable is to be connected
to the top unit, connect the cable be-
fore assembling the ventilation pipe
for better accessibility.
6. Install the ventilation pipe with 2
screws [
Photo
Top unit: 6-2/3
1. Press the neoprene blind rivet nuts
into the front mounting holes
[
Photo
12].
2. Position the unit on the corresponding
holes in the Combi-Duo intermediate
assembly kit [
3. Attach the top unit with two screws in
the holes in the top base plate. Screw
the screws in with a washer
[
Figure
14].
4. If an Ethernet cable is to be connected
to the top unit, connect the cable be-
fore assembling the ventilation pipe
for better accessibility.
5. Install the ventilation pipe with 2
screws [
Photo
5 | Installation
Photo
09].
11].
Photo
13].
11].