1. Press the Alternator Check Button to start the check. The Backlit
LCD Screen will display the following to indicate the unit is analyzing
the alternator:
The Battery Status Icon will light solid and the Alternator Icon will
flash.
2. If the unit detects that the alternator is good, the Backlit LCD
Screen will display the following:
The Battery Status Icon, Alternator Icon, and "ALT GOOD" will light
solid.
3. If the unit detects that the alternator is out of typical voltage range,
the Backlit LCD Screen will display the following:
The Battery Status Icon, Alternator Icon and "ALT" will light solid.
The Fault Icon will flash.
4. Press the Alternator Check Button again to stop the test and turn
off the unit.
IMPORTANT: Always turn the unit off when not in use. Recharge this
unit fully after each use.
Portable Compressor
The built-in 12 volt DC compressor is the ultimate compressor for all
vehicle tires, trailer tires and recreational inflatables. A nozzle adaptor
is supplied that screws onto the end of the Sure Fit
end of the compressor hose. The compressor hose with tire fitting is
stored on the compressor Hose Wrap on the right side of the unit.
Refer to the "Features" illustration for locations of compressor hose.
The Compressor Power Button and Increase ( ) and Decrease ( )
Compressor Pressure Control Buttons are located on the control panel
on the front of the unit.
Before proceeding, check the unit's battery status on the LCD Screen.
Four solid bars in the Battery Icon indicates a full battery. When the
battery level is nearly empty with only one solid bar, the unit MUST be
recharged before use or the unit's built-in low voltage protection will
activate and the compressor will automatically shut down.
The compressor is capable of inflating up to 120 pounds per square
inch (psi) pressure. Return hose to the Hose Wrap after use.
WARNING – To reduce the risk of serious injury or property damage:
Follow all safety instructions found in the "Specific Safety Instructions
for Compressors" section of this instruction manual.
CAUTION – Do not operate compressor continuously for longer
than 10 minutes, as it may overheat. This could damage the
compressor. If the compressor must be operated for longer periods:
every 10 minutes press the Compressor Power Button to turn the
compressor off, then restart after a cooling down period of
18
Nozzle at the free
®