Malfunction analysis
Malfunction code
E5
Overcurrent protection.
H8
Chassis is full of water.
Malfunction of ambient
F1
temperature sensor.
Malfunction of evaporator
F2
temperature sensor.
1.Refrigerant is leaking
F0
2.System is blocked
H3
Overload protection for compressor
E8
Overload malfunction
Outdoor tube temperature
F4
sensor is open/short-circuited.
WARNING
● If there're following phenomenon, please turn off the air conditioner and discon-
nect the power immediately, and then contact dealer immediately.
→ Power cord is overheating or damaged.
→ Abnormal sound during operation.
→ Water leakage
● If operate the air conditioner under abnormal condition, it may cause malfunc-
Disconnect power, and then turn on the unit
again after 10min. If "E5" still exits, please
contact professional person to maintain the unit.
1. Pour out the water inside chassis.
2. If "H8" still exits, please contact professional
person to maintain the unit.
Please contact professional person to deal
with it.
Please contact professional person to deal
with it.
1. Re-energize the unit after turning off and
pulling out the plug for 30min;
2. If there's still malfunction, please contact
after-sales service.
1.Check if the unit is under high-temperature
and high-humidity environment; if ambient
temperature is too high, power off the unit and
then energize it for operation after the ambient
temperature drops to 35℃below.
2. Check if the evaporator and condenser are
blocked by some objects; if yes, take away the
objects, power off the unit and then energize
it for operation.
3. If the malfunction still occur, please contact
our after-sales service center.
Please contact after-sale service person
to deal with it.