SONESSE2 40 ZIGBEE
2.5.Commissioning with a control point only (without TaHoma pro
application)
This chapter describes the commissioning of the drive with a control point only, without using TaHoma pro
application, in the case of TaHoma ready solution.
2.5.1.Link creation between a drive and a control point
The following steps describe how to program a drive that is not set or paired, with an unpaired control point.
CAUTION
Settings are not possible if the control point batteries are too low.
1] Plug in the power supply of the drive.
g If the drive is not set or paired, once plugged in, it goes into programming
mode during 3 min, and its LED blinks orange.
NOTICE
If the drive has left the programming mode, its LED is not blinking:
• Press and hold the PROG button on the drive until the motorised product
moves up and down briefly and its LED blinks orange : the drive is in
programming mode during 3 min.
2] Bring the control point close to the drive then briefly press simultaneously
the Up and Down buttons on the control point: the control point looks for
the closest drive in programming mode.
g When found, the feedback LED on the control point blinks in green, the
drive LED flashes in green, and the motorised product moves up and
down briefly.
g Then the feedback LED on the control point blinks in orange slowly as
long as it is in setting mode.
NOTICE
If the control point does not find a drive nearby, the feedback LED of the control point blinks red after a few seconds,
and the motorised product of the drive does not move: repeat the above procedure. (If the drive is still in
programming mode, repeat only step 2).
NOTICE
If the control point does not find the right drive, please refer to chapter Scanning mode.
©
Copyright
2023 SOMFY ACTIVITES SA. All rights reserved.
1]
ON
N
L
2]
EN
7