4. Commissioning and operation
Radiation characteristics
In order to achieve the best possible transmission quality, the radio link from the end device to the receiving
gateway should be as free from barriers as possible.
The signal strength is slightly to severely affected by concrete walls, metal shields, enclosures and hilly landscapes.
For the best possible transmission power of the antenna, no metal objects, such as pipelines, may be closer than
10 cm [3.93 in] to the antenna.
During installation, observe the radiation characteristics of the instrument and the instructions in the following figure:
330
300
270
10 dB
20 dB
30 dB
240
210
WIKA operating instructions pressure sensor, model PEW-1000
0
30
40 dB
150
180
Horizontal polarisation, x-z plane
Vertical polarisation, x-y plane
60
90
120
Y
Z
X