The modes are activated/deactivated by pressing the
"OK" button briefly.
EN
NB: The factory default for automatic sleep and
power-saving modes are active (20 min and 5 min/10%
respectively). This only applies to wireless sensors.
NB: The power-saving mode is activated
after no load change for a period of time, in order to
preserve the sensor batteries. The reading frequency
of the sensor switches to 1 Hz. A change in load causes
the sensor to switch back on as normal (measuring
frequency 4 Hz).
NB: The automatic sleep mode is activated
after no load change (10% of the SWL of the sensor).
It causes the measurements to stop and preserves the
batteries. The sensor returns to normal operation after
switching the Dynafor
To return to the "Parameters" menu, hold down (for one
second) the left button. The changes are taken into
account when you return to the "Parameters" menu.
5.9.10.2. General sub-menu
.2
The "General" sub-menu is entered by pressing the
"OK" button briefly (item I, fig. 1) when the "General"
icon is highlighted.
A
Measurement unit setting
B
Backlighting setting
C
Configuration of the master or slave mode (not
applicable to the product as it is always treated as
"master")
D
Measurement filter setting. This filtering enables sliding
averaging of the measurements over a fixed period.
The factory default setting is 0.5 seconds.
E
Setting the time tripping delay of the relay switchover.
This delay limits the dynamic effects on a threshold
trip. The factory default setting is 0 seconds
F
Radio communication channel configuration.
G
Date and time setting
14
DMU back on.
TM
§5.9.12
The navigation in the sub-menu is done by using the up
and down buttons. The round, blue indicator updates
according to the position.
The units and configuration mode are set by pressing
the left and right buttons.
The other fields are set by pressing the "OK" button
then the up and down buttons. The values are validated
by pressing the "OK" button briefly.
NB: Changing the channel causes the loss
of the paired sensors. Ten channels are available,
allowing several configurations.
To return to the "Parameters" menu, hold down (for one
second) the left button.
5.9.11. Recording menu
NB: It is not possible with the Dynafor
export the measurements recorded in this menu. See
the Dynafor
HHD manual for how to use this menu.
TM
5.9.12. Language menu
The "Language" screen is entered by pressing the "OK"
button briefly (item I, fig. 1) when the "Language" icon is
highlighted from the main menu.
A
B
A
C
D
E
D
F
G
A
French
B
English
C
German
D
Spanish
E
Italian
F
Dutch
The language is selected by briefly pressing the "OK"
button when the chosen language is highlighted.
DMU to
TM
B
C
F
E