To power up the Dynafor
main ON/OFF switch, located on the front panel on the
device, to turn it on (see figure 1).
5.8.1. WL configuration
When the product is switched on, it automatically
searches
for
environment, on a defined channel. If the channel
is already occupied, it is automatically incremented.
Up to 10 channels, and therefore 10 configurations,
13.1 & §5.8.1
are available. The search time for the devices is one
minute. Once the search is complete, the product
switches to the next screen:
The navigation is done by using the up and down arrow
buttons. (See figure 1.) Sensors that are not paired are
ticked red by default.
Pressing the "OK" button (see figure 1) selects the
sensor or accessory for pairing. The tick will then turn
green.
All sensors and accessories can be selected by
pressing "Select all".
After selecting them all, holding down the "OK" button
starts the pairing of the sensors.
The pairing of a sensor is confirmed when the two
LEDs on the front of the sensor are activated for a few
continuous seconds.
The pairing of accessories is confirmed by the load
display on the sensor.
Once the pairing is finished, the product automatically
switches to the main display.
NB: It is not necessary to pair the sensors every
time the system is started up. Linking will be automatic
once the first pairing has been carried out.
DMU monitor, press the
TM
sensors
and
accessories
5.8.2. RS configuration
When the product is switched on, it automatically pairs
with any sensors and accessories.
The product automatically switches to the main display.
5.8.3. Checking the status of the relays and the
in
its
network
When the product is switched on, it also checks the
relays in the following sequence:
• All the relay LEDs are solid red (see figure 1) for 2
seconds
• All the relay LEDs are solid green (see figure 2) for
2 seconds
• All the relay LEDs are flashing green (see figure 2)
for 2 seconds
• Shutdown of the 5 relay indicators (item B figure 1) if
no threshold is set
• Continuous operation of the network indicator in
green if the network is established (item D figure 1)
NB: In the event of malfunction or loss of one
or more sensors, the network indicator will flash or stay
a solid red.
5.9. Operation
5.9.1. Operation in basic configuration
Basic configuration consists in using a set made up
of one or more sensors and a single Dynafor
monitor.
5.9.2. Operation in multiple and extended
configuration
NB: For further details, please refer to the
associated equipment manuals defined in paragraph 4
Associated equipment.
Multiple configuration consists of connecting up to four
sensors and one or more accessories. The sensors can
have different capacities and there can be two types of
accessory (HHD or AL63).
Accessories are all configured in "Slave" mode.
Contact Tractel
configurations.
5.9.3. Adjusting the associated sensor(s)
NB: If using a Transmitter WL and RS,
adjustment is required to guarantee the precision of
the system. Otherwise, the displayed values cannot be
considered as true.
for any further information on multiple
®
EN
DMU
TM
9