Descargar Imprimir esta página

Tractel Dynafor DMU Manual De Instalación, De Utilización Y De Mantenimiento página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
to have the sensor checked by the manufacturer before
continuing to use it.
5.9.16. Sensor batteries low
EN
If one of the sensors has a low battery, the product will
display the message "Low sensor battery".
Press the "OK" button to make the message disappear.
If wired sensors are used, provided the power supply
is permanent, the product will not display the message.
5.10. Turning the product off
The Dynafor
DMU display unit is turned off by
TM
pressing the interlock ON/OFF button on the front panel
(item B fig.1). The display indicators switch off.
The product can be put in sleep mode by performing
a long press on the keyboard button for standby mode
(item F fig.1) The circuit will remain powered up, but will
not show the load on screen.
5.11. Deinstallation
When deinstalling the product, make sure that power to
the circuit has been turned off beforehand.
Clean the product and store it according to chapters
7.1.
Maintenance
8. Transport and storage.
6. Prohibited uses
THE FOLLOWING ARE FORBIDDEN:
• Modifying the product.
• Exposing the product to any electric and/or
electromagnetic shock.
• Using the product for operations other than those
described in this manual.
18
and
periodic
verification
• Using the product in a highly corrosive environment.
• Using the product in an explosive environment.
• Using the product outside the temperature range of
-20 °C to 50 °C.
• Using the product if it does not appear to be in good
condition.
• Using the product if the markings are missing or
illegible.
See also the prohibited uses in the manuals associated
with the sensors and other accessories.
7. Maintenance and periodic
7.1. Other verifications
Tractel
recommends periodically inspecting the visual
®
condition of the product and cleaning it regularly with
a dry cloth.
8. Transport and storage
During storage and/or transport, the product must be:
• Packed in its original packaging, switched off.
• Stored in a dry location.
• Stored at a temperature between -20°C and 60°C.
• Protected from chemical, mechanical or any other
type of attack.
9. Product disposal and environmental
The product must be disposed of in accordance with the
regulations applicable in the country of use.
The product complies with the requirements of the
REACH regulation and the RoHS directive; it is not
covered by the WEEE directive.
The different product components must be recycled on
the basis of the table below, after separating metal and
synthetic materials. These materials must be recycled
by specialised organisations.
and
At the time of disposal, only competent individuals may
dismantle the product to separate its components.
Component
Housing (plastic)
Printed circuit board and front
panel
verification
protection
To be treated as a
waste of the type
Ordinary waste
Electronics

Publicidad

loading