Descargar Imprimir esta página

Hilti DX 6 Manual De Instrucciones Original página 40

Ocultar thumbs Ver también para DX 6:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 88
6.8
Resetting the cleaning indicator
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
The cleaning indicator is designed to indicate the correct cleaning intervals when the following
cartridges are used:
DX 6 cartridge titanium-gray
DX 6 cartridge, black
▶ Press the operating button at the display and hold it down for 10-12 seconds.
▶ The cleaning indicator is reset.
7
Troubleshooting
WARNING
Risk of explosion! Cartridges may fire (explode) if handled improperly.
▶ Do not use force to remove cartridges from the fastening tool or the magazine strip.
WARNING
Hazard due to hot surfaces! The fastening tool can become hot in use.
▶ Wear protective gloves.
7.1
Fastening tool jams and does not extend
DANGER
Risk of injury by unsecured fastening tool! If the fastening tool jams in the compressed state or if a
cartridge does not fire, the fastening tool might be loaded with the safety off. Unintentional triggering can
cause severe injuries.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Take your finger off the trigger and do not hold your hand in front of the muzzle of the fastener guide.
▶ Keep a fastening tool with the safety off under observation at all times.
1. Keep the fastening tool pressed against the work surface for at least 10 seconds and trigger the fastening
tool again.
2. Lift the fastening tool away from the working surface.
Be sure not to point it toward yourself or other persons!
3. Try to pull the fastener guide to its initial position by hand.
Take your hand off the trigger and do not hold your hand in front of the muzzle!
4. Immediately pull the cartridge strip out of the fastening tool.
If the cartridge strip cannot be removed:
▶ Allow the fastening tool to cool down at a safe location under observation.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Contact Hilti Service.
5. Service the tool.
7.2
Cartridge does not fire when fastening tool is above operating temperature
At all times, make sure that the fastening tool is not pointing toward you or anyone else!
1. Keep the fastening tool pressed against the work surface for at least 10 seconds and trigger the fastening
tool again.
2. If the cartridge still does not fire, wait for 10 seconds and then lift the fastening tool away from the work
surface.
3. Immediately pull the cartridge strip out of the fastening tool.
▶ If the cartridge strip cannot be removed:
▶ Allow the fastening tool to cool down at a safe location under observation.
▶ Contact Hilti Service.
4. Service the tool.
5. Move the cartridge to a safe location.
32
English
33
33
2232121
*2232121*

Publicidad

loading

Este manual también es adecuado para:

Dx 6-f8Dx 6-f10Dx 6-mxDx 6 ie-lDx 6 ie-xl