The following repair works are described here:
• Removing the cover plate and mounting frame
• Replacing the solenoid valve
• Replacing the regulating screw
• Replacing the lip seal of the flush pipe
• Mounting the mounting frame and cover plate
• Manual flush time setting
Removing the cover plate and
mounting frame
1
2
2
1
3
4
15º
2
5
Remove the battery box (battery-operated flush
control, batteries can be replaced).
1
Disconnect the cables (Step 2 - only for a mains-
operated flush control).
2
Service
DE
EN
FR
IT
NL
ES
PT
DK
2
NO
SE
FI
IS
PL
HU
SK
CZ
SL
HR
SR
EE
LV
1
LT
BG
RO
GR
TR
RU
AE
CN
JP
27