Descargar Imprimir esta página

geberit HyTronic 116035SN1 Instrucciones De Mantenimiento página 38

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 103
Service
Interval flush [IntFlush] [IntervSp]
Flushes after the last use once a certain interval has elapsed [IntervalT] [IntervalZ] (menu item 54). The interval is
restarted with every use. The flush time is determined by [IntFlushT] [IntervSpZ] (menu item 53).
[FlshTime]
[FlshTime]
< [IntervalT]
Hybrid mode [HybridMod]
The flush is not released during use (waterless operation). A periodic flush is released once the time-out period or interval
has elapsed. The flush time is determined by [HybFlshT] (menu item 56).
• Use mode [1]: Flushes once the time-out [HybTimOut] has elapsed (menu item 57). No flush is released if the time-out
is still active. The time-out starts:
-
From the first use
-
From the next use once the previous time-out has elapsed
[HybTimOut]
• Time mode [2]: Flushes once the interval [HybIntT] has elapsed (menu item 58). No flush is released if the interval is
still active. The interval starts:
-
From the first use
-
Once the previous interval has elapsed, regardless of the number of uses
[FlshTime]
[HybIntT]
38
[IntFlushT]
[IntervalT]
> [IntervalT]
[HybFlshT]
[HybFlshT]
[FlshTime]
[IntervalT]
[HybTimOut]
[HybIntT]
t
t
[HybFlshT]
t
[HybIntT]

Publicidad

loading