Follow OSHA guidelines for Permissible Exposure Limits (PEL's) for various
fumes and gases.
Follow the American Conference of Governmental Industrial Hygienists recom-
mendations for Threshold Limit Values (TLV's) for fumes and gases.
Have a recognized specialist in Industrial Hygiene or Environmental Services
check the operation and air quality and make recommendations for the specific
welding or cutting situation.
10. Always keep hoses away from welding/cutting spot. Examine all hoses and cables
for cuts, burns, or worn areas before each use. If any damaged areas are found,
replace the hoses or cables immediately.
11. Read and understand all instructions and safety precautions as outlined in
the manufacturer's Manual for the material you will weld or cut.
12. Proper cylinder care. Secure cylinders to a cart, wall, or post, to prevent them
from falling. All cylinders should be used and stored in an upright position. Never
drop or strike a cylinder. Do not use cylinders that have been dented. Cylinder
caps should be used when moving or storing cylinders. Empty cylinders should be
kept in specified areas and clearly marked "empty."
13. Never use oil or grease on any inlet connector, outlet connector, or cylinder
valves.
14. Use only supplied Torch on this Inverter Air Plasma Cutter. Using components
from other systems may cause personal injury and damage components within.
15. People with pacemakers should consult their physician(s) before using this pro-
duct. Electromagnetic fields in close proximity to a heart pacemaker could cause
interference to, or failure of the pacemaker.
16. USE PROPER EXTENSION CORD. Make sure your extension cord is in good
condition. When using an extension cord, be sure to sue one heavy enough to
carry the current your product will draw. An undersized cord will cause a drop in
line voltage resulting in loss of power and overheating. A 50 foot extension cord
must be at least 12 gauges in diameter, and a 100 foot extension cord must be at
least 10 gauges in diameter. If in doubt, use the next heavier gauge. The smaller
the gauge number, the heavier the cord.
PROVIDED EQUIPMENT:
Cable with mass clamp.
Cable with TIG burner WP-26 along with accessories:
Collets: 1.6mm / 2.4mm / 3.2mm.
Ceramic nozzles no 5, 6, 7.
Long cap.
Tungsten.
Cable with electrode holder MMA.
Gas hose.
Mask.
Hammer.
Brush.
26
EN
Rev. 28.04.2022
RoHS
CERTIFICATES –welder has been manufactured in accordance
with CE and RoHS certificates. It guarantees long life time and
high quality of the device.
MOSFeT
The welder uses MOSFET technology. This technology (as no
other) ensures the highest efficiency. In comparison to the cur-
rent consumption amount we gather over-proportional power
amount. This results in the efficiency of 93%! Welding current
is very stable and it ensures perfect fusion weld. Thanks to the
MOSFET technology, the machine is light and compact.
Standard supply voltage = the welder is supplied by 230 V
voltage from the single-phase socket (230V +/- 10%).
1 PH
INERT GAS = for WIG / TIG welding it is necessary to use
GAS
inert gas (e.g. argon).
FANS = very efficient fans ensure the optimal heat release
during the welder operation.
LEGEND:
LED display = it displays the current value of the current
1
intensity.
Power supply indicator = after switching on the machine, this
2
control lamp lights-up.
Overloading / failure = the lamp lights up in case of two cases:
3
a) Machine failure, it can not be operated.
b) Welder exceeded the standard overloading time, it switches
into the emergency mode and next – it turns off. It means, that
the device goes off as a result of temperature and overheating
control.
During this process, the warning lamp lights-up on the front
panel. In such case it is not necessary to pull the plug from the
socket. In order to cool the device, the fan may still operate.
If the red lamp does not light up, it means that the device is
cooled down to the working temperature and it can be used
again.
Rev. 28.04.2022