12. Place the Spray/Prime Switch (F) to the Prime Position.
PRIME AND FLUSH
Before each use, the sprayer must be primed and flushed to remove the storage
fluid out of the sprayer. Follow these guidelines when priming and flushing:
Use water to thoroughly flush the system if you will be spraying water-based
materials.
Use a compatible oil-based flushing solvent or mineral spirits to thoroughly
flush the system if you will be spraying oil-based materials.
If changing from oil-based spraying to water-based spraying, flush the system
thoroughly with water first. The water flowing out from the Primer Outlet Tube
(H) should be clear and free from any solvent before you begin spraying the
water-based material. If changing from water-based spraying to oil-based
spraying, flush the system thoroughly with a compatible oil-based flushing
solvent or mineral spirits first. The solvent flowing from the Primer Outlet Tube
(H) should not contain any water.
Always use a grounded metal waste or solvent pail.
See the Electrical Safety section.
Always aim the gun at the inside wall of the waste or solvent pail to avoid fluid
splashing back on your skin or into your eyes.
1. Turn the power ON / OFF Switch (B) to the OFF position and unplug the
sprayer.
.
- 25 -