Attachment; Operation - EuroLite UV-TUBE SLIM COMPLETE SET Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 80° C.
UV illuminants are hazardous waste which needs to be disposed of appropriately.
Please dispose of the unusable UV illuminants in accordance with the current legal regulations.
Procedure:
Step 1: Press the buttons together on one end of the fixture and pull this end out a few centimeters.
Step 2: If replacing the tube lamp, remove the old lamp from the socket.
Step 3: Insert the new tube lamp into the lamp-socket and carefully push the end back into place.

Attachment

Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: On the baseplate, there are holes for the installation.
Step 2: Hold the baseplate onto the location where the device is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes and fix the screws.
Step 5: Install the device onto the screws.
Before taking into operation for the first time, the installation has to be approved by an expert!

OPERATION

After you connected the device to the mains, the UV-tube lamp needs 3-4 minutes warm-up time until it
reaches full lighting output.
DANGER TO LIFE!
13/27
00027046.DOC, Version 1.3

Publicidad

Tabla de contenido
loading

Tabla de contenido