Starting Up And Programming; Connection To The Electricity Supply And Check; Programming Sequence - Erreka FENIX Manual Del Instalador

Accionador de techo
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

STARTING UP AND PROGRAMMING

1

CONNECTION TO THE ELECTRICITY SUPPLY AND CHECK

1 Plug the operator into the electricity supply.
In order to know the requirements of the
grid connection, see "Electrical power supply
installation" on page 53.
The correct operation of the operator and of the
complete system will only be achieved after
programming. However, prior to programming it
is necessary to check that all the elements work,
carrying out the checks listed below.
2

PROGRAMMING SEQUENCE

60
Installation Manual
Before carrying out any door movement,
ensure there is no person or object in the radius
of action of the door and the operation
mechanisms.
2 Briefly press the |+ and |- buttons of the operator
control board once or twice to check correct
operation.
3 Activate the wall key or push button to check it
works.
O
Before starting programming, manually move the
door to interlock the drag carriage.
1 Pressing the SET button will carry out the door open/
close
programming
programming" on page 61).
2 Pressing the CODE button will carry out the radio
code personalisation and programming (see "Radio
code
personalisation
page 61).
3 The parameter adjustment is made by pressing the
|+ button for 3 or more seconds (see "Parameter
adjustment" on page 62), in other words:
• 1: the maximum opening thrust
• 2: the maximum closing thrust
• 3: the functioning mode (step-by-step or
automatic), and standby time in automatic mode
• 4: precise adjustment of the lower limit of the
door
• 5: slowdown distance
• 6: type of transmitter (fixed code or roller code)
(see
"Door
open/close
and
programming"
on

Publicidad

Tabla de contenido
loading

Tabla de contenido