AutoSense
Gap Sensor
Adjustment
Réglage du
capteur de
détection
automatique
d'espace
980003-100 Rev. B
Load labels into the printer. D o n o t use th e
auto-dispense/peeler mode for this procedure. Press and
hold the PAUSE and CANCEL control buttons with the
power on. Release the CANCEL button first and then
release the PAUSE button.
The printer will start feeding labels automatically. The
printer will automatically adjust the gap sensor and
measure the label length.
After the sensor has been adjusted, the printer will enter
DUMP mode and print the standard information label.
Press the FEED button once to switch the printer back to
normal operation. If the Error indicator light (continues)
to glow AMBER/ORANGE, refer to Appendix A for
troubleshooting information.
Mettez en place les étiquettes dans l'imprimante.
N'utilisez pas le mode distribution automatique pour cette
procédure. Maintenez enfoncés les boutons PAUSE et
CANCEL, l'imprimante étant sous tension. Relâchez
d'abord le bouton CANCEL, puis le bouton PAUSE.
L'imprimante commence l'avance automatique des
étiquettes. Elle ajuste automatiquement le capteur
d'espace et mesure la longueur des étiquettes.
Après l'ajustement du capteur, l'imprimante passe en
mode DUMP et imprime l'étiquette d'information
standard.
Appuyez une fois sur le bouton FEED pour remettre
l'imprimante en mode normal. Si le voyant error continue
à s'allumer en JAUNE ou en ORANGE, consultez les
informations de dépannage de l'annexe A.